Estimate runtime from simultaneous running watts or measured 24-hour energy, with a separate check against continuous output.
About 3 minutes You’ll need: battery capacity, running watts or measured daily energy, and reserve
Battery runtime calculator for household backup power planning
Calculations run in this browser; inputs stay out of analytics. A draft saves here after your first change unless you turn saving off. You choose separately whether to save a result to My Household Plan or copy a permitted share link.
If the same appliances use 900 Wh of AC energy over 24 hours, that is an average energy load of 37.5 W. Their simultaneous running demand can still be 150 W or more; this illustrative running figure is checked against continuous output, while motor startup demand remains a separate question. The measured energy total describes use and does not have reserve or conversion losses applied in advance.
For an illustrative 1,000 Wh battery, a 20% reserve and 85% conversion-efficiency assumption leave 680 Wh of estimated usable AC energy. At 37.5 W average use, that gives about 18.1 hours (680 ÷ 37.5). These percentages are example assumptions, not ratings for a particular battery. Temperature, standby draw, changing use, and manufacturer limits can change the result.
DOE's storage overview explains energy versus power capacity and conversion losses; it does not prescribe the reserve or efficiency used in this example.
| Nameplate capacity | Illustrative usable AC energy (20% reserve, 85% efficiency) | At 37.5 W avg (900 Wh/24h) | At 75 W constant load | At 150 W constant load |
|---|---|---|---|---|
| 500 Wh class | 340 Wh | ~9.1 hours | ~4.5 hours | ~2.3 hours |
| 1,024 Wh class | 696 Wh | ~18.6 hours | ~9.3 hours | ~4.6 hours |
| 2,048 Wh class | 1,393 Wh | ~37.1 hours | ~18.6 hours | ~9.3 hours |
Use either a constant running-load estimate or measured total AC energy for the selected devices over 24 hours. The system still needs enough continuous and surge power, safe placement, compatible charging, and a real test with the exact devices.
Estimate usable AC energy as nameplate watt-hours × (1 − reserve as a decimal) × conversion efficiency as a decimal. Divide by constant running watts for hours of runtime. For measured-energy mode, divide usable energy by the measured 24-hour AC watt-hours divided by 24. These are planning estimates; continuous output and motor startup need separate checks.
Watts measure power at a moment. Watt-hours measure stored energy. A battery must have enough continuous and surge power for the devices and enough usable energy for the planned runtime.
The estimate holds back the reserve you choose and applies a conversion-efficiency assumption. Actual usable energy also varies by battery limits, inverter, temperature, age, settings, and load.
No. Motors and compressors can draw more power while starting than while running. Check the exact appliance demand and the battery system's surge rating, duration, and manufacturer limits; this remains unresolved even when you enter measured daily energy.
Yes, as a planning estimate. Choose a constant running-load estimate or enter measured total AC energy for the same selected loads over 24 hours. The tool applies your reserve and conversion-efficiency assumptions once. Startup power, temperature, charging, and manufacturer limits still need separate verification.
No. Battery runtime does not establish food temperature or safe storage time. Use the Food Safety Outage Calculator linked under Further reading for the separate refrigerator and freezer timeline question.
Plan first. Buy what is missing.
After estimating your watt-hours and continuous watts, compare documented specifications and startup limits. These examples are not selected from your calculator answers.
EcoFlow
When to consider another option Loads requiring 240 V or more than the continuous output rating.
Read the fit and limitationsBLUETTI
When to consider another option 240 V loads or a whole-home installation requirement.
Read the fit and limitations